Synology NAS: check USB UPS protection before an outage

Share
Workers on a transmission pylon beneath clouds
Contents

At a glance

Connect a compatible USB UPS, check DSM standby settings and plan a controlled test. Separate battery backup from recoverable copies of your files.

Define what this check will establish

A NAS can have battery power without knowing when that battery is nearly empty. This guide is for an administrator of a Synology NAS using a compatible USB-connected uninterruptible power supply, or UPS. The outcome is a documented configuration and a test plan for orderly interruption and recovery. It is not a guarantee against file loss, and we have not tested your hardware. The current Synology help page reviewed here is labelled DSM 7.4; follow the help for your installed version if its labels differ.

In Synology’s documented Standby Mode, services stop and storage volumes are unmounted before battery power is exhausted. The NAS may therefore stop serving files while some hardware remains powered. Do not judge the outcome solely by a lit power indicator or an unavailable shared folder. Record which state you expected and how you will recognise it. [1]

Prepare the equipment and recovery path

Start during a maintenance period, with permission from anyone relying on the NAS. Save open work and identify running backups, virtual machines and other jobs that an interruption would affect. Verify a separate recoverable copy of important files first. NCSC guidance emphasises knowing how to restore a backup and checking that it contains the required data. A successful UPS test does not establish either of those things.

Record the NAS model, installed DSM version and exact UPS model. Consult Synology’s compatibility list and the UPS manufacturer’s manual. Check the supported output in watts and the runtime information for the connected load; a large VA number is not a promised runtime. Include every device that will share the battery outlets. If the battery reports a fault, the load exceeds a rating or compatibility is unclear, resolve that issue before treating the setup as protected. [3][4]

Connect power and the USB status link

Follow the UPS manual for installation, charging and safe connection. Identify battery-backed outputs rather than assuming every socket provides battery power. Connect the NAS power supply to an appropriate protected output. Connect the UPS communication cable to a NAS USB port as a separate connection. Power delivery and status communication are different paths: having one does not prove the other works.

Write down which outlet powers the NAS and which USB port receives status. If a network switch is needed to observe the test, account for its power too. This guide covers direct USB signalling to one NAS; a network UPS server, SNMP device or high-availability cluster needs its own documented arrangement. Do not enable a network server merely because the checkbox is visible. Confirm the physical arrangement before changing software settings. [2][3]

Enable support and verify the device

Sign in to DSM with an account permitted to change hardware settings. Open Control Panel > Hardware & Power > UPS. Enable UPS support and select USB UPS as the connection type. Open Device Information and check that information is available for the connected unit. Save the intended settings with Apply, then reopen the page to confirm they persisted. Menu labels may be translated in your installation.

If the device is absent or information is unavailable, stop the acceptance check. Compare the model against the compatibility information, inspect the communication cable and consult the product instructions. Do not substitute a guessed SNMP address or assume a USB charging cable carries the required data. Record the symptom and any change made. Only continue once the device can be identified consistently; a ticked support box alone is insufficient evidence. [2]

Choose a standby policy deliberately

DSM offers a low-battery trigger or a custom delay before standby. Choose the policy for your actual workload and supported battery runtime, leaving time for services to stop. The documentation says a low-battery condition takes precedence if it occurs before the selected delay. A custom value is consequently not a promise that file services will remain available for that entire interval.

Review the separate option to switch off the UPS after standby before enabling it. Synology warns that power-off behaviour varies by model. Also review Control Panel > Hardware & Power > General if automatic restart after a power failure is required. Treat the standby trigger, UPS power-off command and subsequent restart as separate decisions. Save the original values before changing them. There is no universal delay appropriate for every battery age, load and service mix. [1][2]

Plan a controlled interruption test

Prepare a written sequence before simulating any outage. Identify the manufacturer-approved way to interrupt the UPS input while preserving its required safety connections. Arrange local access, an observer and a way to restore normal supply. Do not experiment with building wiring, remove protective earth or pull the NAS power lead as a substitute for testing the UPS. A hardwired system needs a qualified person following its own procedure.

For a worked acceptance record, create an ordinary test file with a recognisable sentence, close it and keep a separate copy. Note the normal UPS status, configured trigger and start time. During the authorised interruption, record whether the unit reports battery operation and whether DSM follows the expected standby policy. If you cannot confirm the expected state, restore supply using the approved procedure and investigate. Do not repeatedly drain the battery to force a result. A battery self-test alone does not prove that DSM received and acted on a shutdown signal. [1][3]

Check recovery and investigate failures

After restoring stable supply, observe what the NAS actually does under the saved restart policy. If it remains off, use the model’s documented startup procedure; do not assume automatic restart was enabled. Once DSM is reachable, inspect storage health, relevant event messages and the services you normally use. Reopen the test file and compare it with the separate copy. Also confirm that the UPS has returned to its normal supply state.

Distinguish a missing network connection from a stopped NAS. A switch without backup power can make a healthy device appear unreachable during the interruption. If DSM never detected battery operation, investigate the communication path. If it detected the event but did not behave as configured, preserve the settings, timestamps and logs for support. If storage reports a problem, stop routine writes and follow the documented recovery route rather than repeatedly restarting. Record the result as incomplete until the discrepancy is explained. [1]

Acceptance record: distinguish each result

CheckEvidence to record
CommunicationDevice identified in DSM
InterruptionBattery event and expected standby
RecoveryStorage and services checked
DataTest file compared with separate copy

Keep a record and a separate backup

Keep the configuration, equipment models, test conditions and observed result together. An example completion note can say that USB identification, the selected standby trigger, recovery and a sample file check passed under the recorded load. It should not claim that every application, future outage or battery condition has been tested. Repeat the assessment after changing the UPS, battery, DSM version, attached load or relevant services.

The UPS addresses interruption of electrical supply; it does not create another copy of a deleted or encrypted file. Keep recovery testing separate from power testing, using our related guide to restore backup files into another folder. The practical completion criteria are modest and verifiable: DSM identifies the UPS, the saved policy matches your intended interruption response, a controlled test has an explained outcome, and important data remains independently recoverable. If the outage simulation has not been performed, describe the setup as configured but not yet tested. [4]

Evidence & sources

Source record: · Checked:

Record limits · DSM 7.4 help and independent backup guidance reviewed November 23, 2026. Documentation-based procedure; no physical UPS test performed.

  1. [1]Source reported

    Standby Mode stops services and unmounts volumes.

    Supporting excerpt: UPS | DSM - Synology Knowledge Center

    Original quotation

    it stops all services and unmounts volumes
    UPS | DSM - Synology Knowledge Center ↗

    Source language: EN · Captured Nov 23, 2026

  2. [2]Source reported

    DSM supports a USB UPS connection type.

    Supporting excerpt: UPS | DSM - Synology Knowledge Center

    Original quotation

    Select USB UPS from the UPS type drop-down menu.
    UPS | DSM - Synology Knowledge Center ↗

    Source language: EN · Captured Nov 23, 2026

  3. [3]Source reported

    Battery capacity and runtime need verification.

    Supporting excerpt: How do I choose a suitable UPS? - Synology Knowledge Center

    Original quotation

    verify the battery capacity and available runtime of the UPS
    How do I choose a suitable UPS? - Synology Knowledge Center ↗

    Source language: EN · Captured Nov 23, 2026

  4. [4]Source reported

    Backups need a restoration and contents check.

    Supporting excerpt: Small organisations guide to cyber security | Backing up your data | National Cyber Security Centre

    Original quotation

    check that it contains all your important data
    Small organisations guide to cyber security | Backing up your data | National Cyber Security Centre ↗

    Source language: EN · Captured Nov 23, 2026